VS

Home > General Purpose UPS > Tripp Lite SmartPro SMARTINT2200VS

Tripp Lite SmartPro SMARTINT2200VS

Details Rankings Comparisons Alternatives Related
Tripp Lite SmartPro SMARTINT2200VS
Compare with other General Purpose UPS
 Compare
Tripp Lite SmartPro SMARTINT2200VS VS
All other General Purpose UPS
General
Form Factor Tower 
Manufacturer Tripp Lite  
Product Line Smartpro 
Product Name Smartpro 2200va Tower Ups 
Manufacturer Part Number SMARTINT2200VS  
Manufacturer Website Address Www.tripplite.com 
Specifications
Load Capacity 2.20 Kva/1.60 Kw  vs 3.3% General Purpose UPS have 2.20 kVA/1.60 kW
Backup/Run Time 0.32 Hour 800 W Half Load, 0.12 Hour 1.60 Kw Full Load 
Interfaces/Ports 2 X Db-9 Serial, 2 X Usb 
Output Voltage 230 V Ac Nominal 
Input Voltage Range 240 V AC  
Receptacles 8 X Iec 320-c13, 1 X Iec 320-c19  vs 0.7% General Purpose UPS have 8 x IEC 320-C13 1 x IEC 320-C19
Frequency 50 Hz, 60 Hz 
Batteries User Replaceable Hot-swappable 
Limited Warranty
2 Year (0.33 Year lower than average)
vs
2.33 Year

Plug/Connector Type IEC 320-C20   vs 3% General Purpose UPS have IEC 320-C20
Certifications & Standards UL1778 CE 62040  
Filtering Emi/rfi Ac Noise Suppression 
Additional Information Maintains Regulated 230v Nominal Output During Brownouts And Overvoltages From 151 To 282v Communications Ports Support Messaging Of Ups And Line Power Status, Including On-battery, Low-battery, Power Restored, Ac Line Voltage, Dc Battery Voltage And Remaining Battery Capacity Supports Timed Inverter Shutoff After Unattended Shutdown, Activate Self-test And Ups Output Power Control For Scheduled Or Immediate Reboot Of Connected Devices Brownout Correction: Input Voltages Between 177 And 199 Are Boosted By 14% Severe Brownout Correction: Input Voltages Between 151 And 176 Are Boosted By 30% Cooling Method: Fan Cold Start: Yes, Inverter Can Be "cold Started" To Enable Temporary Ac Output During A Power Failure Output Frequency Regulation: Line Mode: Passes Line Frequency Of 50/60hz +/-10% Battery Mode: Inverter Output Regulated To 50/60hz +/-0.5hz 
Battery Recharge Time
4 Hour (59.38 Hour lower than average)
vs
63.38 Hour

Network Management Snmp Manageable Optional 
Switching Time
4 MS (0.09 MS lower than average)
vs
4.09 MS

Emergency Power OFF Yes 
Overload Protection Via Branch Rated 10a Output Breaker 
Voltage Handling -19 To +8% Utility Regulation, 5% Battery Regulation 
Temperature 32 F (0 C) To 104 F (40 C) Operating, 5 F (-15 C) To 122 F (50 C) Storage 
Humidity 0 To 95% Non-condensing Relative Humidity 
Status Indicators Five Front Panel Leds: Line Power Battery Power Battery Low/replace Voltage Regulation 
Waveform Type Pulse-width Modulated Sine Wave 
Alarm Utility Power Failure 
Surge Energy Rating
1800 J (1129.72 J higher than average)
vs
670.28 J

Battery Life 3 Year To 6 Year - Depending On Usage 
Color Gray 
Circuit Breaker 10 A Output - 
Dimensions
Width
9.3 " (31.4 " lower than average)
vs
40.70 "

Depth
12 " (7.2 " lower than average)
vs
19.20 "

Height
14.3 " (9.53 " lower than average)
vs
23.83 "

Weight (Approximate)
54 lb (29.75 lb lower than average)
vs
83.75 lb



Scroll To Top