General
Form Factor Tower 
Manufacturer Tripp Lite  
Product Name TE600 UPS  
Manufacturer Part Number TE600  
Manufacturer Website Address Www.tripplite.com 
Specifications
Load Capacity 600 VA/425 W   vs 0.2% General Purpose UPS have 600 VA/425 W
Backup/Run Time 0.37 Hour 300 Va Half Load, 0.12 Hour 600 Va Full Load 
Interfaces/Ports 1 X Db-9 
Output Voltage 120 V Ac Single-phase 
Input Voltage Range 120 V Ac Single-phase 
Receptacles 3 X Nema 5-15r  vs 1.2% General Purpose UPS have 3 x NEMA 5-15R
Frequency
60 Hz (0.95 Hz lower than average)
vs
60.95 Hz

Batteries Sealed Lead Acid User Replaceable Hot-swappable 
Limited Warranty
2 Year (0.33 Year lower than average)
vs
2.33 Year

Plug/Connector Type NEMA 5-15P   vs 46.7% General Purpose UPS have NEMA 5-15P
Certifications & Standards Ul, Cul, Nom, 
Filtering EMI / RFI  
Additional Information Provides Connected Equipment With Continuous Power During Short And Long Duration Loss Of Commercial Power Line-interactive Voltage Regulation Corrects Brownouts And Overvoltages From 75 To 147 Volts Back To Usable 120v Output Levels, Without Using Battery Power Supports Loads Up To 600va / 425 Watts Up To 74 Minutes Runtime With 32 Line Norstar Compact Ics Phone System (requires Approx. 110va) 22 Minutes Half Load Runtime (300va/210 Watts), 7 Minutes Full Load Runtime (600va/425 Watts) 6 Protected Outlets Total (3 Ups Supported & 3 Surge-suppression Only); 6-ft. Cord Db9 Serial Port For Network Interface; Snmp Compatible Complete Surge Protection And Emi/rfi Noise Filtering 4 Diagnostic Leds Indicate Ac Present, On Battery, Voltage Correction & Battery Low/replace Battery Replacement Door 
Battery Recharge Time 4 Hour Minimum 
Network Management Snmp Manageable Optional 
Temperature 32 F (0 C) To 104 F (40 C) Operating 
Humidity 0 To 95% Non-condensing 
Status Indicators 4 Front Panel Leds Indicate Line Power Status, Battery Power Status, Battery Low/replace Status And Voltage Regulation Operation 
Alarm On Battery 
Power Cord/Cable
0.5 ft (3.64 ft lower than average)
vs
4.14 ft

Battery Life 3 To 6 Year 
Color White 
System Requirements Typical Applications: Small Business Telephone Systems, Voicemail Systems, Hubs, Routers, Bridges, Concentrators, Ip Telephony, Desktop Pcs, Small Network Fileservers And More. 
Dimensions
Width
5.3 " (35.4 " lower than average)
vs
40.70 "

Depth
7.3 " (11.9 " lower than average)
vs
19.20 "

Height
10.8 " (13.03 " lower than average)
vs
23.83 "

Weight (Approximate)
19 lb (64.75 lb lower than average)
vs
83.75 lb



Scroll To Top

saved