Specifications |
Load Capacity |
|
5 Kva/4 Kw |
vs |
1.3% General Purpose UPS have 5 kVA/4 kW
|
|
Backup/Run Time |
|
0.63 Hour 2.50 Kva Half Load, 0.27 Hour 5 Kva Full Load |
|
|
|
Interfaces/Ports |
|
2 X Usb, 2 X Db-9 |
|
|
|
Output Voltage |
|
120 V Ac Single-phase, 208 V Ac Single-phase |
|
|
|
Input Voltage Range |
|
208 V Ac Single-phase |
|
|
|
Receptacles |
|
1 X Nema L14-30r, 1 X Nema L6-30r, 10 X Nema 5-15r, 2 X Nema 5-20r |
vs |
0.2% General Purpose UPS have 1 x NEMA L14-30R 1 x NEMA L6-30R 10 x NEMA 5-15R 2 x NEMA 5-20R
|
|
Frequency |
|
60 Hz (0.95 Hz lower than average)
|
vs |
|
|
Batteries |
|
Sealed Lead Acid User Replaceable Hot-swappable |
|
|
|
Limited Warranty |
|
2 Year (0.33 Year lower than average)
|
vs |
|
|
Plug/Connector Type |
|
NEMA L6-30P |
vs |
4.5% General Purpose UPS have NEMA L6-30P
|
|
Certifications & Standards |
|
Ul1778 (usa), Cul (canada), Fcc Class A (emissions), Nom (mexico), Conforms To Ieee 587 / Ansi C62.41 Specifications |
|
|
|
Filtering |
|
EMI / RFI |
|
|
|
Additional Information |
|
Large 5000va / 4000 Watt Output Capacity With Full Time Sine Wave Output Offers Guaranteed Compatibility With All Equipment Types High Power Density 5kva Power Module And Battery Pack Occupy Only 3 Rack Spaces (3u) Each (ups And Battery Pack Use 6u When Installed) 38 Minutes Half Load Runtime, Expandable Runtime With Multiple External Battery Packs (part# Bp48v60rt3u) Line Interactive Voltage Regulation Corrects Severe Brownouts And Overvoltages Without Using Battery Power Dual Voltage Output Is Simultaneously Compatible With Both 208 And 120v Equipment 14 Total Outlets (120v: 10 5-15r, 2 5-20r / 208v: 1 L6-30r, 1 L14-30r) Diagnostic Leds Provide Visual Indication Of 17 Separate Performance Conditions Included Poweralert Software Provides E-mail Or Pager Notification Of Power Problems And The Simultaneous Automatic Unattended Shutdown Of Multiple Servers 4 Built-in Communications Ports (2-db9, 2-usb) For Remote Monitoring And Unattended Shutdown Slot For Snmp/web Card Snmpwebcard And Environmental Sensor Envirosense For Remote Communications In Large Ip Environments 8 Customized Load Management Receptacles Can Be Individually Powered Off And Back On Again Via Software Interface To Reboot Remote Equipment Or Automatic "load Shedding" Of Less Critical Loads To Extend Battery Runtime For The Most Critical Equipment Emergency Power Off (epo) Interface For Emergency Shutoff In Large Facilities Hot-swappable / User Replaceable Batteries Allow On-site Battery Replacement Through The Front Panel Without Powering Off Connected Equipment Or Removing The Ups From The Rack Ups Battery Set Ships Fully Assembled And Ready For Connection To The Power Module, No Time Consuming, Connection Of Individual Internal Batteries By User Is Necessary $250,000 Ultimate Lifetime Insurance (usa & Canada Only). No Warranty Cards Required For Coverage! 2 Year Manufacturers Product Warranty |
|
|
|
Battery Recharge Time |
|
4 Hour (59.38 Hour lower than average)
|
vs |
|
|
Network Management |
|
Snmp Manageable Optional |
|
|
|
Switching Time |
|
4 MS (0.09 MS lower than average)
|
vs |
|
|
Emergency Power OFF |
|
Yes |
|
|
|
Overload Protection |
|
Resettable Circuit Breaker (3 Total, 15a Each) |
|
|
|
Modular Slots |
|
1 X Communications Slot |
|
|
|
Temperature |
|
32 F (0 C) To 104 F (40 C) Operating |
|
|
|
Humidity |
|
0 To 95% Non-condensing Relative Humidity |
|
|
|
Status Indicators |
|
5 Front Panel Leds - Green 5 Front Panel Leds - Green Power Led, Green Voltage Correction Led, 3 Color Battery Charge Led, 3 Color Output Load Led, Red Battery Warning Led |
|
|
|
Waveform Type |
|
Sine Wave |
|
|
|
Alarm |
|
On Battery, Low Battery, Overload |
|
|
|
Power Cord/Cable |
|
10 ft (5.86 ft higher than average)
|
vs |
|
|
Battery Life |
|
3 Year To 6 Year |
|
|
|
System Requirements |
|
Typical Applications: Ideal For Centralized Ups Protection Of Critical 208 And 120 Volt Equipment In Server Rooms, Internetworking Closets And Telecommunications Systems In Rackmount Or Tower Applications. Common Applications Include Any Mix Of Servers, Workstations, Hubs, Routers, Concentrators, Ip Telephony And Traditional Pbx Switching System |
|
|
|