Specifications |
Load Capacity |
|
900 VA/475 W |
vs |
0.2% General Purpose UPS have 900 VA/475 W
|
|
Backup/Run Time |
|
0.17 Hour 237 W Half Load, 0.05 Hour 475 W Full Load |
|
|
|
Interfaces/Ports |
|
1 X Usb |
|
|
|
Output Voltage |
|
120 V Ac Nominal, 115 V Ac Nominal |
|
|
|
Input Voltage Range |
|
120 V Ac Nominal |
|
|
|
Receptacles |
|
4 X Nema 5-15r - Battery/surge-protected, 4 X Nema 5-15r - Surge-protected |
vs |
1.9% General Purpose UPS have 4 x NEMA 5-15R - Battery/Surge-protected 4 x NEMA 5-15R - Surge-protected
|
|
Frequency |
|
60 Hz Output, 60 Hz Input |
|
|
|
Batteries |
|
User Replaceable Hot-swappable |
|
|
|
Limited Warranty |
|
3 Year (0.67 Year higher than average)
|
vs |
|
|
Plug/Connector Type |
|
NEMA 5-15P |
vs |
46.7% General Purpose UPS have NEMA 5-15P
|
|
Certifications & Standards |
|
Ul1778 (tuv) Cul (tuv) Nom Fcc Class B |
|
|
|
Filtering |
|
EMI / RFI |
|
|
|
Additional Information |
|
Low Voltage Transfer To Battery Power: Switches To Battery Power As Line Voltage Decreases To 89v Or Less, Switches Back To Ac Mode As Line Voltage Increases To 94v Or Higher High Voltage Transfer To Battery Power: Switches To Battery Mode As Line Voltage Increases To 139v Or Higher, Switches Back To Ac Mode As Line Voltage Decreases To 135v Or Lower Network Monitoring Port: Single Built-in Usb Port Supports On Battery, Low Battery And Power Restored Messaging. Interface Supports Timed Inverter Shutoff After Unattended Shutdown. Compatible With Tripp Lite's Poweralert And Watchdog Service Software Compatible With Tripp Lite's Watchdog System Service To Restore Operation To Locked Equipment Through Soft Reboot Of Application / Os Or Hard Power Off/on Reboot Of Connected Equipment Ideal For Unattended Kiosk Applications Switches: Includes 2 Front Panel Switches - One Main On/off Power Switch And One Dual Function "alarm Cancel" / "self Test" Button Entry-level Pcs, Networked Workstations, Point-of-sale Equipment, Small Business Phone Systems, Audio/video Equipment And Home Theater Systems. Ideal For Sensitive Electronic Applications In Areas Where Brownout Conditions Are Common |
|
|
|
Software Included |
|
Poweralert Software |
|
|
|
Switching Time |
|
3 MS (1.09 MS lower than average)
|
vs |
|
|
Current |
|
12 A Input Current |
|
|
|
Voltage Handling |
|
5% Battery Regulation |
|
|
|
Green Compliant |
|
Yes |
|
|
|
Green Compliance Certificate/Authority |
|
Rohs |
|
|
|
Temperature |
|
32 F (0 C) To 104 F (40 C) Operating, 5 F (-15 C) To 122 F (50 C) Storage |
|
|
|
Humidity |
|
0 To 95% Non-condensing Relative Humidity |
|
|
|
Status Indicators |
|
Front Panel Lcd Screen With Blue Backlight Offers: Continuous Input Line Voltage Data Ups Status Information On Line Power Status Battery Power Status Battery Charge Level Voltage Regulation Operation |
|
|
|
Waveform Type |
|
Pulse-width Modulated Sine Wave |
|
|
|
Alarm |
|
Ac Input Failure |
|
|
|
Input Current |
|
12 A (4.38 A lower than average)
|
vs |
|
|
Surge Energy Rating |
|
870 J (199.72 J higher than average)
|
vs |
|
|
Battery Life |
|
4 Year To 6 Year |
|
|
|
Color |
|
Black |
|
|
|