Specifications |
Load Capacity |
|
3 Kva/2.70 Kw |
vs |
2.8% General Purpose UPS have 3 kVA/2.70 kW
|
|
Backup/Run Time |
|
0.17 Hour 1.35 Kw Half Load, 0.08 Hour 2.70 Kw Full Load |
|
|
|
Interfaces/Ports |
|
Usb, Serial |
|
|
|
Output Voltage |
|
127 V AC, 120 V AC, 110 V AC |
|
|
|
Input Voltage Range |
|
83 V Ac To 159 V Ac Configurable |
|
|
|
Receptacles |
|
4 X Nema 5-15r - Battery Backup System, 1 X Nema L5-30r - Battery Backup System, 2 X Nema 5-20r - Battery Backup System |
vs |
0.2% General Purpose UPS have 4 x NEMA 5-15R - Battery Backup System 1 x NEMA L5-30R - Battery Backup System 2 x NEMA 5-20R - Battery Backup System
|
|
Frequency |
|
50 Hz, 60 Hz |
|
|
|
Batteries |
|
8 X Spill Proof Valve-regulated Lead Acid (vrla) User Replaceable Hot-swappable |
|
|
|
Limited Warranty |
|
2 Year (0.33 Year lower than average)
|
vs |
|
|
Plug/Connector Type |
|
NEMA 5-30P |
vs |
0.5% General Purpose UPS have NEMA 5-30P
|
|
Certifications & Standards |
|
Safety Ul 1778, C-ul Listed Emissions Fcc Part 15, Class A Network Surge Ul 497 B Transportation Ista Procedure 1a Certification |
|
|
|
Additional Information |
|
Configurable Input Voltage Window Allows The Ups To Be Properly Matched To The Incoming Utility Power Optional External Battery Cabinets Provide Extended Battery Runtime For Applications That Require Longer Backup Time Rotatable Display Panel The Ups Automatically Adjusts To The Input Frequency, 50hz Or 60hz Advance Early Warning Of Ups System Status Full Sequenced Battery Testing. Higher Output Power Factor (0.9) Batteries Are Conveniently Located Behind The Front Bezel Of The Unit Wider Input Voltage Window Prolongs Battery Life Reduced Installation Time And Costs Ups Is Shipped With Batteries Connected And Charged Automated Shutdown Software Allows You To Monitor Communication Between The Ups And A Server Liebert Intellislot Web Card Provides Snmp And Web-based Management T-slot, Accepts 15a Plug, (1) Nema L5-30r |
|
|
|
Battery Recharge Time |
|
5 Hour (58.38 Hour lower than average)
|
vs |
|
|
Network Management |
|
Snmp Manageable Optional |
|
|
|
Switching Time |
|
6 MS (1.91 MS higher than average)
|
vs |
|
|
Emergency Power OFF |
|
Yes |
|
|
|
Voltage Handling |
|
5% Battery Regulation |
|
|
|
Temperature |
|
32 F (0 C) To 104 F (40 C) Operating, 5 F (-15 C) To 104 F (40 C) Storage |
|
|
|
Humidity |
|
0 To 90% Non-condensing Relative Humidity |
|
|
|
Waveform Type |
|
Sine Wave |
|
|
|
Power Cord/Cable |
|
10 ft (5.86 ft higher than average)
|
vs |
|
|
Surge Energy Rating |
|
570 J (100.28 J lower than average)
|
vs |
|
|
System Requirements |
|
Windows (98 And Later) Built-in Power Management Functions Provide Monitoring Of Ups Status And Manage The Automatic Orderly Shutdown Of The Computer If A Power Outage Ever Exceeds The Battery Capacity Of The Ups. Liebert Usb Shutdown And Monitoring Software Is Provided |
|
|
|
Altitude |
|
9,843 ft |
|
|
|
Protection Type |
|
Surge, Lightning |
|
|
|
Additional Warranty Information |
|
Optional One-year And Three-year Extensions Also Available. |
|
|
|