Load Capacity |
|
300 Va/180 W |
vs |
700 Va/450 W |
|
Backup/Run Time |
|
0.53 Hour 150 Va Half Load, 0.23 Hour 300 Va Full Load |
vs |
0.92 Hour 225 W Half Load, 0.37 Hour 450 W Full Load |
|
Interfaces/Ports |
|
1 X Usb |
vs |
Db-9 Rs-232 Serial, Usb |
|
Output Voltage |
|
120 V Ac Single-phase |
vs |
120 V Ac Nominal |
|
Input Voltage Range |
|
120 V Ac Single-phase |
vs |
120 V Ac Nominal |
|
input voltage |
|
110 V Ac |
vs |
110 V Ac |
|
Receptacles |
|
3 X Nema 5-15r |
vs |
6 X Nema 5-15r |
|
Frequency |
|
60 Hz |
vs |
60 Hz |
|
Batteries |
|
Sealed Lead Acid |
vs |
|
|
Limited Warranty |
|
2 Year |
vs |
2 Year |
|
Plug/Connector Type |
|
Nema 5-15p |
vs |
Iec 320-c14 |
|
Certifications & Standards |
|
Ul1778 (usa), Cul (canada), Fcc Class B (emissions), Nom (mexico), Fcc Part 68 / Industry Canada (telecommunications), Conforms To Ieee 587 / Ansi C62.41 Specifications |
vs |
Tested To Ul1778 (usa), Csa C22.2 No. 107.3 (canada), Ce (iec62040 / European Union), Fcc Class A (emissions) |
|
Filtering |
|
Emi / Rfi |
vs |
Emi / Rfi |
|
Additional Information |
|
Omnismart300 Line Interactive Ups System Offers Voltage Regulation And Battery Support, Plus Complete Ac And Dialup/dsl Line Surge Suppression Supports Entry Level Pc Systems For Up To 30 Minutes During Power Failures To Enable A Safe System Shutdown Supports A Maximum Load Of 300va/180 Watts For 14 Minutes And A Half Load Of 150va/90 Watts For 32 Minutes Automatic Voltage Regulation (avr) Circuits Correct Brownouts As Low As 75 Volts And Overvoltages As High As 147 Back To Normal 120 Volt Levels Without Using Battery Power Attractive Gray Tower Configuration Includes 3 Battery Supported Outlets Built-in Usb Port Supports Poweralert Ups Power Management Software (available Via Free Download At Tripplite.com) And Cabling Provides Monitoring Of In-depth Site Power Conditions, Full Ups Status And Fault Warnings, Output Load Level And Load Bank Power Control Supports Tripp Lite's Watchdog Service Monitoring/rebooting Software (part# Watchdogsw) Built-in Dataline Suppression Jacks Protect A Single Dialup Phone / Dsl Line Built-in Audible Alarm And 4 Front Panel Leds Indicate Ups System And Line Power Status 500va / 300 Watt Power Handling Ability Supports A Variety Of Computer, Internetworking, Telecom And Consumer Electronics Equipment Supports Battery Replacement Via Built-in Access Panel Compatible With 120v / 60hz Applications For Usa, Canada, Mexico And More 2 Year Manufacturer's Warranty $200,000 Connected Equipment Insurance (usa & Canada Only) |
vs |
Ideal For Military, Relief Or Other Applications Where Low-voltage 120v Output Is Required Switches:includes 2 Front Panel Switches One Main On/off Power Switch And One Dual Function "alarm Cancel" / "self Test" Button Low Voltage Transfer To Battery Power: Switches To Battery Power As Line Voltage Drops To 83v Or Lower (159v At 230v Nominal), Resets To Line Power As Line Voltage Increases To 87v Or Higher (167v At 230v Nominal) High Voltage Transfer To Battery Power: Switches To Battery Power As Line Voltage Increases To 147v Or Higher (282v At 230v Nominal), Resets To Line Power When Line Voltage Drops To 143v Or Lower (274v At 230v Nominal) |
|
Battery Recharge Time |
|
4 Hour |
vs |
4 Hour |
|
Network Management |
|
|
vs |
Snmp Manageable Optional |
|
Switching Time |
|
4 MS |
vs |
4 MS |
|
Emergency Power OFF |
|
|
vs |
Yes |
|
Dataline Protection |
|
Rj-11 Phone/fax/internet/dsl |
vs |
|
|
Overload Protection |
|
|
vs |
Input Circuit Breaker |
|
Current |
|
|
vs |
4.80 A Maximum Input Current |
|
Voltage Handling |
|
|
vs |
-21 To +8% Output |
|
Temperature |
|
32 F (0 C) To 104 F (40 C) Operating |
vs |
|
|
Humidity |
|
0 To 95% Non-condensing Relative Humidity |
vs |
|
|
Status Indicators |
|
4 Front Panel Leds Indicate Line Power Status, Battery Power Status, Battery Low/replace Status And Voltage Regulation Operation |
vs |
|
|
Power Cord/Cable |
|
0.5 ft |
vs |
|
|
Input Current |
|
|
vs |
4.8 A |
|
Battery Life |
|
3 Year To 6 Year |
vs |
|
|
cancel