Load Capacity |
|
1 Kva/500 W |
vs |
700 Va/450 W |
|
Backup/Run Time |
|
0.30 Hour 250 W Half Load, 0.12 Hour 500 W Full Load |
vs |
0.92 Hour 225 W Half Load, 0.37 Hour 450 W Full Load |
|
Interfaces/Ports |
|
Usb |
vs |
Db-9 Rs-232 Serial, Usb |
|
Output Voltage |
|
230 V Ac Nominal |
vs |
120 V Ac Nominal |
|
Input Voltage Range |
|
240 V Ac |
vs |
120 V Ac Nominal |
|
input voltage |
|
220 V Ac |
vs |
110 V Ac |
|
Receptacles |
|
6 X Iec 320-c13 - Surge-protected |
vs |
6 X Nema 5-15r |
|
Frequency |
|
60 Hz, 50 Hz |
vs |
60 Hz |
|
Batteries |
|
User Replaceable |
vs |
|
|
Limited Warranty |
|
2 Year |
vs |
2 Year |
|
Plug/Connector Type |
|
Iec 320-c14 |
vs |
Iec 320-c14 |
|
Certifications & Standards |
|
Ul1778 Ce 62040 Gost Saso Iram |
vs |
Tested To Ul1778 (usa), Csa C22.2 No. 107.3 (canada), Ce (iec62040 / European Union), Fcc Class A (emissions) |
|
Filtering |
|
Emi/rfi Ac Noise Suppression |
vs |
Emi / Rfi |
|
Additional Information |
|
Regulates Brownouts As Low As 159 Volts Back To Usable Levels Without Using Battery Power Usb Port And Cable Enables Unattended Shutdown In The Case Of Extended Power Failure Supports Battery Replacement Via Built-in Access Panel Brownout Correction: Input Voltages Between 159 And 199 Are Boosted By 14% Ac Suppression Response Time: Instantaneous Cooling Method: Convection High Voltage Transfer To Battery Power: Yes Cold Start: Yes, Inverter Can Be "cold Started" To Enable Temporary Ac Output During A Power Failure Poweralert Software Is Available At Www.tripplite.com Output Frequency Regulation: Line Mode: Passes Line Frequency Of 50/60hz +/-10% Battery Mode: Inverter Output Regulated To 50/60hz +/-0.5hz |
vs |
Ideal For Military, Relief Or Other Applications Where Low-voltage 120v Output Is Required Switches:includes 2 Front Panel Switches One Main On/off Power Switch And One Dual Function "alarm Cancel" / "self Test" Button Low Voltage Transfer To Battery Power: Switches To Battery Power As Line Voltage Drops To 83v Or Lower (159v At 230v Nominal), Resets To Line Power As Line Voltage Increases To 87v Or Higher (167v At 230v Nominal) High Voltage Transfer To Battery Power: Switches To Battery Power As Line Voltage Increases To 147v Or Higher (282v At 230v Nominal), Resets To Line Power When Line Voltage Drops To 143v Or Lower (274v At 230v Nominal) |
|
Battery Recharge Time |
|
4 Hour |
vs |
4 Hour |
|
Network Management |
|
|
vs |
Snmp Manageable Optional |
|
Switching Time |
|
4 MS |
vs |
4 MS |
|
Emergency Power OFF |
|
|
vs |
Yes |
|
Dataline Protection |
|
Rj-11 Dsl/fax/modem/phone |
vs |
|
|
Overload Protection |
|
|
vs |
Input Circuit Breaker |
|
Current |
|
|
vs |
4.80 A Maximum Input Current |
|
Voltage Handling |
|
5% Battery Regulation |
vs |
-21 To +8% Output |
|
Temperature |
|
32 F (0 C) To 104 F (40 C) Operating, 5 F (-15 C) To 122 F (50 C) Storage |
vs |
|
|
Humidity |
|
0 To 95% Non-condensing Relative Humidity |
vs |
|
|
Status Indicators |
|
Four Front Panel Leds: Line Power Battery Power Battery Low/replace Load |
vs |
|
|
Waveform Type |
|
Pulse-width Modulated Sine Wave |
vs |
|
|
Alarm |
|
Utility Power Failure |
vs |
|
|
Power Cord/Cable |
|
5.91 ft |
vs |
|
|
Input Current |
|
|
vs |
4.8 A |
|
Surge Energy Rating |
|
1920 J |
vs |
|
|
Battery Life |
|
3 Year To 6 Year - Depending On Usage |
vs |
|
|
Color |
|
Black |
vs |
|
|
cancel