Add another Item to this comparison
Add Item
All attributes
Differences
Similarities
General
product type
Line-interactive Ups
vs
Line-interactive Ups
Form Factor
Tower
vs
Tower
brand name
Tripp Lite
vs
Ultra
Manufacturer
Tripp Lite
vs
Streak Products, Inc
Product Line
Omni
vs
Product Name
Omni Vs 1000va Tower Ups
vs
Ult33046 2000va Tower Ups
Product Model
vs
Ult33046
Manufacturer Part Number
Omnivsint1000
vs
Ult33046
Manufacturer Website Address
Www.tripplite.com
vs
Www.ultraproducts.com
Product Series
Vs
vs
Specifications
Load Capacity
1 Kva/500 W
vs
2 Kva/1.20 Kw
Backup/Run Time
0.30 Hour 250 W Half Load, 0.12 Hour 500 W Full Load
vs
0.02 Hour 1.20 Kw Full Load
Interfaces/Ports
Usb
vs
Output Voltage
230 V Ac Nominal
vs
100 V Ac To 120 V Ac
Input Voltage Range
240 V Ac
vs
100 V Ac To 120 V Ac
input voltage
220 V Ac
vs
110 V Ac
Receptacles
6 X Iec 320-c13 - Surge-protected
vs
2 X Nema 5-15r - Surge-protected, 4 X Nema 5-15r - Battery/surge-protected
Frequency
60 Hz, 50 Hz
vs
60 Hz
Batteries
User Replaceable
vs
Maintenance-free Sealed Lead Acid
Limited Warranty
2 Year
vs
3 Year
Plug/Connector Type
Iec 320-c14
vs
Certifications & Standards
Ul1778 Ce 62040 Gost Saso Iram
vs
Filtering
Emi/rfi Ac Noise Suppression
vs
Additional Information
Regulates Brownouts As Low As 159 Volts Back To Usable Levels Without Using Battery Power Usb Port And Cable Enables Unattended Shutdown In The Case Of Extended Power Failure Supports Battery Replacement Via Built-in Access Panel Brownout Correction: Input Voltages Between 159 And 199 Are Boosted By 14% Ac Suppression Response Time: Instantaneous Cooling Method: Convection High Voltage Transfer To Battery Power: Yes Cold Start: Yes, Inverter Can Be "cold Started" To Enable Temporary Ac Output During A Power Failure Poweralert Software Is Available At Www.tripplite.com Output Frequency Regulation: Line Mode: Passes Line Frequency Of 50/60hz +/-10% Battery Mode: Inverter Output Regulated To 50/60hz +/-0.5hz
vs
Battery Recharge Time
4 Hour
vs
6 Hour Typical
Software Included
vs
Ups Mon Software
Switching Time
4 MS
vs
4 MS
Dataline Protection
Rj-11 Dsl/fax/modem/phone
vs
Type F Connector Coaxial Cable Line, Rj-45 Ethernet, Rj-11 Phone
Overload Protection
vs
Unit Input: Breaker Or Fuse For Overload & Short Circuit Protection
Voltage Handling
5% Battery Regulation
vs
5% Output, 25% Input
Temperature
32 F (0 C) To 104 F (40 C) Operating, 5 F (-15 C) To 122 F (50 C) Storage
vs
Humidity
0 To 95% Non-condensing Relative Humidity
vs
Status Indicators
Four Front Panel Leds: Line Power Battery Power Battery Low/replace Load
vs
Waveform Type
Pulse-width Modulated Sine Wave
vs
Alarm
Utility Power Failure
vs
Power Cord/Cable
5.91 ft
vs
Surge Energy Rating
1920 J
vs
Battery Life
3 Year To 6 Year - Depending On Usage
vs
Color
Black
vs
Dimensions
Width
5.3 "
vs
5.1 "
Depth
7.3 "
vs
15 "
Height
10.8 "
vs
7.6 "
Weight (Approximate)
21.2 lb
vs
31.97 lb
Compare Tripp Lite Omni OMNIVSINT1000 vs Ultra ULT33046 General Purpose UPS