Load Capacity |
|
1 Kva/500 W |
vs |
1.50 Kva/940 W |
|
Backup/Run Time |
|
0.30 Hour 250 W Half Load, 0.12 Hour 500 W Full Load |
vs |
0.23 Hour 470 W Half Load, 0.08 Hour 940 W Full Load |
|
Interfaces/Ports |
|
Usb |
vs |
Usb |
|
Output Voltage |
|
230 V Ac Nominal |
vs |
120 V Ac Nominal |
|
Input Voltage Range |
|
240 V Ac |
vs |
120 V Ac |
|
input voltage |
|
220 V Ac |
vs |
110 V Ac |
|
Receptacles |
|
6 X Iec 320-c13 - Surge-protected |
vs |
6 X Nema 5-15r - Battery Backup System, 2 X Nema 5-15r - Surge-protected |
|
Frequency |
|
60 Hz, 50 Hz |
vs |
60 Hz |
|
Batteries |
|
User Replaceable |
vs |
2 User Replaceable Hot-swappable |
|
Limited Warranty |
|
2 Year |
vs |
2 Year |
|
Plug/Connector Type |
|
Iec 320-c14 |
vs |
Nema 5-15p |
|
Certifications & Standards |
|
Ul1778 Ce 62040 Gost Saso Iram |
vs |
Tested To Ul1778 (usa) Csa (canada) Nom (mexico) Fcc Class B (emissions) Rohs |
|
Filtering |
|
Emi/rfi Ac Noise Suppression |
vs |
Emi / Rfi Ac Noise Suppression |
|
Additional Information |
|
Regulates Brownouts As Low As 159 Volts Back To Usable Levels Without Using Battery Power Usb Port And Cable Enables Unattended Shutdown In The Case Of Extended Power Failure Supports Battery Replacement Via Built-in Access Panel Brownout Correction: Input Voltages Between 159 And 199 Are Boosted By 14% Ac Suppression Response Time: Instantaneous Cooling Method: Convection High Voltage Transfer To Battery Power: Yes Cold Start: Yes, Inverter Can Be "cold Started" To Enable Temporary Ac Output During A Power Failure Poweralert Software Is Available At Www.tripplite.com Output Frequency Regulation: Line Mode: Passes Line Frequency Of 50/60hz +/-10% Battery Mode: Inverter Output Regulated To 50/60hz +/-0.5hz |
vs |
Output Voltage Regulation: Line Mode: Sine Wave Line Voltage 120v (-18% / +8%) Battery: Pwm Sine Wave Output 120v +/-5% |
|
Battery Recharge Time |
|
4 Hour |
vs |
4 Hour |
|
Software Included |
|
|
vs |
Poweralert Ups Monitoring Software |
|
Switching Time |
|
4 MS |
vs |
4 MS |
|
Dataline Protection |
|
Rj-11 Dsl/fax/modem/phone |
vs |
Tel/dsl/ethernet |
|
Current |
|
|
vs |
12 A |
|
Voltage Handling |
|
5% Battery Regulation |
vs |
|
|
Green Compliant |
|
|
vs |
Yes |
|
Green Compliance Certificate/Authority |
|
|
vs |
Rohs |
|
Temperature |
|
32 F (0 C) To 104 F (40 C) Operating, 5 F (-15 C) To 122 F (50 C) Storage |
vs |
|
|
Humidity |
|
0 To 95% Non-condensing Relative Humidity |
vs |
|
|
Status Indicators |
|
Four Front Panel Leds: Line Power Battery Power Battery Low/replace Load |
vs |
|
|
Waveform Type |
|
Pulse-width Modulated Sine Wave |
vs |
|
|
Alarm |
|
Utility Power Failure |
vs |
|
|
Power Cord/Cable |
|
5.91 ft |
vs |
|
|
Input Current |
|
|
vs |
12 A |
|
Surge Energy Rating |
|
1920 J |
vs |
|
|
Battery Life |
|
3 Year To 6 Year - Depending On Usage |
vs |
|
|
Color |
|
Black |
vs |
|
|
cancel