General
product type   Online Ups vs   Online Ups  
 
[X]
Add Comment about “product type”

Form Factor   15u Rack-mountable vs   2u Tower/rack Mountable  
 
[X]
Add Comment about “Form Factor”

brand name   Apc vs   Liebert  
 
[X]
Add Comment about “brand name”

Manufacturer   American Power Conversion Corp vs   Emerson Network Power  
 
[X]
Add Comment about “Manufacturer”

Product Line   Symmetra vs     
 
[X]
Add Comment about “Product Line”

Product Name   Symmetra Rm 12kva Scalable Ups vs   Gxt3-3000rt120 3000va Tower/rack Mountable Ups  
 
[X]
Add Comment about “Product Name”

Product Model    vs   Gxt3-3000rt120  
 
[X]
Add Comment about “Product Model”

Manufacturer Part Number   Syp12k12rmt vs   Gxt3-3000rt120  
 
[X]
Add Comment about “Manufacturer Part Number”

Manufacturer Website Address   Www.apc.com vs   Www.liebert.com  
 
[X]
Add Comment about “Manufacturer Website Address”

Product Series    vs   Gxt3  
 
[X]
Add Comment about “Product Series”

Add Comment about “General

cancel
Specifications
Load Capacity   
12 kVA
vs   3 Kva/2.70 Kw  
 
[X]
Add Comment about “Load Capacity”

Backup/Run Time   0.28 Hour 4.20 Kw Half Load, 0.09 Hour 8.40 Kw Full Load vs   0.07 Hour 2.70 Kw Full Load, 0.23 Hour 1.35 Kw Half Load  
 
[X]
Add Comment about “Backup/Run Time”

Interfaces/Ports   1 X Db-9 Rs-232 Serial, 1 X Rj-45 vs   Usb  
 
[X]
Add Comment about “Interfaces/Ports”

Output Voltage   240 V Ac, 208 V Ac Nominal vs   120 V Ac Configurable, 115 V Ac Configurable, 110 V Ac Configurable, 127 V Ac Configurable  
 
[X]
Add Comment about “Output Voltage”

Input Voltage Range   155 V Ac To 276 V Ac Mains Operation, 208 V Ac Nominal vs   120 V Ac Nominal  
 
[X]
Add Comment about “Input Voltage Range”

input voltage   
220 V Ac
vs   110 V Ac
 
 
[X]
Add Comment about “input voltage”

Receptacles   3 X Nema L6-30r, 6 X Nema L6-20r, 1 vs   6 X Nema 5-20r, 1 X Nema L5-30r  
 
[X]
Add Comment about “Receptacles”

Frequency   50 Hz Input, 57 To 63 Hz Output, 60 Hz Input vs     
 
[X]
Add Comment about “Frequency”

Batteries   Maintenance-free Sealed Lead Acid Hot-swappable vs   User Replaceable Hot-swappable  
 
[X]
Add Comment about “Batteries”

Limited Warranty   
2 Year
vs   2 Year
 
 
[X]
Add Comment about “Limited Warranty”

Plug/Connector Type   Hardwired vs   Nema L5-30p  
 
[X]
Add Comment about “Plug/Connector Type”

Certifications & Standards   Csa Fcc Part 15 Class A Ul 1778 vs   Ul 1778 Cul Listed Fcc Part 15 Class A=cispr22 Class B Iec 62040-2 2nd Ed Ista Procedure 1a  
 
[X]
Add Comment about “Certifications & Standards”

Filtering    vs   Emi/rfi Noise  
 
[X]
Add Comment about “Filtering”

Additional Information   Audible Alarms Automatic Voltage Regulation (avr) Error: No Translation Found Hot Swap Electronics Informative Interface Input Power Factor Correction Lcd Alphanumeric Display Multiple System Shutdown Overload Indicator Overvoltage Correction Replace Batt Indicator Scalable Power Capacity Scalable Run Time Software User Replaceable Batteries vs     
 
[X]
Add Comment about “Additional Information”

Battery Recharge Time   3 Hour Typical vs   3 Hour
 
 
[X]
Add Comment about “Battery Recharge Time”

Network Management   Snmp Manageable vs   Snmp Manageable  
 
[X]
Add Comment about “Network Management”

Software Included    vs   Liebert Multilink Shutdown Software  
 
[X]
Add Comment about “Software Included”

Emergency Power OFF   Yes vs     
 
[X]
Add Comment about “Emergency Power OFF”

Overload Protection    vs   Input Circuit Breaker  
 
[X]
Add Comment about “Overload Protection”

Modular Slots   1 X Smartslot vs     
 
[X]
Add Comment about “Modular Slots”

Temperature   5 F (-15 C) To 113 F (45 C) Non-operating, 32 F (0 C) To 104 F (40 C) Operating vs     
 
[X]
Add Comment about “Temperature”

Humidity   0 To 95% Operating, 0 To 95% Non-condensing Non-operating vs     
 
[X]
Add Comment about “Humidity”

Bypass Switch   Manual vs   Maintenance, Manual, Automatic, Internal  
 
[X]
Add Comment about “Bypass Switch”

Waveform Type   Sine Wave vs     
 
[X]
Add Comment about “Waveform Type”

Alarm   Low Battery, On Battery vs     
 
[X]
Add Comment about “Alarm”

Color   Black vs     
 
[X]
Add Comment about “Color”

Altitude   0 Ft To 50000 Ft Non-operating, 0 Ft To 10000 Ft Operating vs     
 
[X]
Add Comment about “Altitude”

Thermal Dissipation   2834 Btu/h vs     
 
[X]
Add Comment about “Thermal Dissipation”

Sound Emission   
62 dB(A)
vs     
 
[X]
Add Comment about “Sound Emission”

Battery Management   Intelligent Battery Management vs     
 
[X]
Add Comment about “Battery Management”

Power Consumption   8400 W Operating vs     
 
[X]
Add Comment about “Power Consumption”

Add Comment about “Specifications

cancel
Dimensions
Width   
19 "
vs   16.9 "
 
 
[X]
Add Comment about “Width”

Depth   
29 "
vs   23.7 "
 
 
[X]
Add Comment about “Depth”

Height   
26.3 "
vs   3.4 "
 
 
[X]
Add Comment about “Height”

Weight (Approximate)   
452 lb
vs   61.7 lb
 
 
[X]
Add Comment about “Weight (Approximate)”